Kermit 95 Terminal Types

As of: Kermit 95 2.0
Date: 7 June 2002

Kermit 95 2.0 supports 40 terminal emulations:

ADM3A
The Lear-Siegler ADM-3A terminal. No F-keys.

AIXTERM
For accessing IBM AIX systems. Compatible with the AIXTERM window on AIX workstations, and the AIXTERM termcap / terminfo entry. Has F1-F12 keys, also Shift-F1-F12.

ANSI-BBS (*)
For accessing most BBSs. 8 bits, color, line- and box-drawing, "ANSI graphics". As defined in the DOS 5.0 manual. Function keys F1-F4 send what VT100 sends, F5-F12 undefined.

AT386 (*)
For accessing (SCO) Unixware and (Sunsoft) Interactive UNIX systems. Has 60 Function keys F1-F12 plus various versions with Shift, Ctrl, Ctrl-Shift, etc.

Avatar/0+ (*)
For accessing BBSs that support certain advanced features. If a BBS supports Avatar/0+, this is normally negotiated automatically when you log in to it. F1-F4, like ANSI-BBS.

BA80
The Nixdorf BA80 terminal (Germany), used for accessing Nixdorf computers. Has PA (function) keys 1-12.

BETERM (*)
BeBox console, the preferred terminal type for accessing the BeBox and BeOS.

DG200
Data General DASHER 200, for accessing AOS/VS, DG/UX, and other Data General platforms. Has function keys F1-F12, which can be modified by Shift, Ctrl, or Ctrl-Shift, plus some others (e.g. Alt-F1-F5, Alt-Shift-F1-F5, Ctrl-Alt-F1-F5).

DG210
Data General DASHER 210, for accessing AOS/VS, DG/UX, and other Data General platforms. F-keys as for DG200.

DG217
Data General DASHER 217, for accessing AOS/VS, DG/UX, and other Data General platforms. Includes both DG and UNIX modes, as well as alternate character sets -- Math/Symbol, Line Drawing, Word Processing. F-keys as for DG200.

HEATH19
The Heath-19 or Zenith-19 terminal. Has PF1-4 like VT100.

HFT
IBM's High Function Terminal type, used for accessing AIX and other IBM platforms that support it. Has F1-F12, Shift-F1-F12, Ctrl-F1-F12.

HP2621A
The Hewlett Packard 2621A terminal. Has F1-F16. F9-F16 are entered by Shift-F1-F8.

HPTERM (*)
Hewlett Packard's generic HPTERM specification, used on HP-UX in HPTERM windows, and compatible with various specific HP terminals such as those in the 700 series. F keys as for HP2621A.

HZ1500
The Hazeltine 1500 terminal. Has F1-F12.

IBM3151
The IBM 3151 terminal. This emulation is just enough to support termcap and terminfo driven applications on Unix. A complete keyboard mapping is provided as well as the IBM 3151 graphics character set. None of the special forms modes are (yet) implemented. Has F1-F12, Alt-F1-F12, Shift-Alt-F1-F12.

LINUX
The Linux console. Has 60+ function keys, produced by F-keys (and some others) in various combinations with Shift, Ctrl, and Alt.

QANSI (*)
The QNX ANSI terminal. F1-F10.

QNX
The QNX console. F1-F12, Shift F1-F12.

SCOANSI (*)
The SCO version of ANSI, used by SCO UNIX, ODT, and OpenServer, and Caldera Open UNIX. Has 60 function keys, like AT386. WARNING: The host name is ANSI, but Kermit's name is SCOANSI, to distinguish it from ANSI-BBS, which is different. When making Telnet connections, set Kermit's terminal type to SCOANSI and its Telnet terminal-type to ANSI:

  set terminal type scoansi
  set telnet terminal-type ansi

SNI-97801
The Siemens Nixdorf Bildschirmeinheit 97801-5xx (Germany), for use with SINIX. Downloadable character-sets, fonts, and compose tables are not supported. Has tons of function keys produced by various combinations of F-keys with Shift, Ctrl, and Alt.

TTY
Teletypewriter. This is equivalent to no terminal emulation at all.

TVI910+
The Televideo 910+ terminal. F1-F12, Shift-F1-F12, Alt-F1-F6, Alt-Shift-F1-F6.

TVI925
The Televideo 925 terminal. F1-F12, Shift-F1-F12, Alt-F1-F6, Alt-Shift-F1-F6.

TVI950
The Televideo 950 terminal. F1-F12, Shift-F1-F12, Alt-F1-F6, Alt-Shift-F1-F6.

VC404
The Volker Craig 404 terminal. F1-F12.

VIP7809
Partial emulation of the Honeywell VIP-7809 terminal. In fact, this is VT-102 emulation with minor modifications sufficient to allow access to Honeywell DPS-6 systems.

VT52
The Digital Equipment Corporation VT52 terminal. Has PF keys 1-4 on F1-F4 but no F keys.

VT100
The industry-standard 7-bit Digital Equipment Corporation VT100 terminal, with color extensions. Has PF keys 1-4 on F1-F4, but no F keys.

VT102
Like VT100, but with character insertion and deletion capabilities and several other functions added, and with color extensions.

VT220
The industry-standard 8-bit Digital Equipment Corporation VT220 terminal with color extensions. Has PF keys 1-4 on F1-F4, plus 20 F-keys, 1-20, of which only F5-F20 are usable, on F5-F12 and Shift-F1-F10.

VT220PC
VT220 with a PC keyboard.

VT320
The industry-standard 8-bit Digital Equipment Corporation VT320 terminal with color extensions, plus many features of the VT420, VT520, and DECterm. F-keys as for VT220.

VT320PC
VT320 with a PC keyboard.

VTNT
VTNT is a proprietary Microsoft terminal definition used by the Telnet Server distributed with Windows 2000/XP and NT Services for Unix.

WY30
The Wyse model 30 terminal, plus most of the capaibilities of the Wyse 30+ and 35 models. Multiple Windows, display controls, and certain other features are not currently supported.

WY50
The Wyse model 50 terminal. Multiple Windows, display controls, and certain other features are not currently supported. F1-F12, Shift-F1-F12, Alt-Shift-F1-F6, and others.

WY60
The Wyse model 60 terminal, plus most of the features of the Wyse 120, 160, and 350 models. Multiple Windows, display controls, and certain other features are not currently supported. F keys as for WY50.

WY160
The Wyse model 160 terminal, plus most of the features of the Wyse 120 and 350 models. Multiple Windows, display controls, and certain other features are not currently supported.

WY370
The Wyse model 370 terminal, similar to VT320 but with additional color capabilities. F-keys as for WY60, plus some more.

The names in the list are those used in the Terminal Type box on the Terminal page of the Dialer entry notebook, and by the SET TERMINAL TYPE command. These names are also sent to the host in Telnet terminal type negotiations unless you have specified a TELNET terminal-type name to override it.


ANSI Terminal Types

Whenever a (PC) ANSI terminal type is chosen, the following actions are executed automatically:

The normal mode of operation for any ANSI terminal type is to converse with a host application that uses a PC code page as its character set, and whose code page is the same as your code page. This is because ANSI terminal emulation is generally used for applications where there is a lot of line and box drawing -- "graphics" simulated by colored character cells.

In some environments, however, the host sends Latin-1 or other codes for accented or special characters. In such cases, you can set your terminal character set to Latin-1 (or other set) AFTER selecting an ANSI terminal type, for example:

  set terminal type scoansi                 ; Sets CP437
  set terminal remote character-set latin1  ; Set it to Latin-1

But Latin-1 (and Latin-2, Cyrillic, Hebrew, etc) do not include the many box-drawing characters needed for ANSI emulation, and the simple form of the SET TERMINAL CHARACTER-SET command shown above assigns Latin-1 to all of G1, G2, and G3. Thus you must also ensure that your PC code page remains available as an alternate character set by using the more specific form of the command, which is:

  SET TERMINAL REMOTE-CHARACTER-SET name [ Gn ]

This lets you change your remote character set without having to respecify (or even know) your local PC character set (or code page). The optional Gn field designates the named set to the specified terminal graphics table, G0, G1, G2, or G3 (you can specify more than one) according to ISO 4873 and 2022 rules.


HPTERM Emulation

This is a functional HPTERM (Hewlett Packard Xterm) emulation, but lacking color and multiple pages. When function keys are programmed and/or labeled, you can view the labels on a popup help screen using the new \Kfnkeys verb, which is assigned by default to Alt-f.

When the HPTERM emulation is selected, character sets are assigned as follows:

   Remote: GL->G0: US ASCII (94 chars)
           GR->G1: Hewlett Packard Roman 8 (96 chars)
               G2: HP Line Drawing Graphics (96 chars)
               G3: HP Line Drawing Graphics (96 chars)


SNI-97801 Emulation

The SNI-97801 is an advanced terminal designed specificly with the multiple language market in mind. Kermit 95 does not support the following features of the terminal:

The SNI-97801 has a keyboard with more than 42 function and editing keys which cannot be mapped directly to a PC keyboard. K95 provides keyboard verbs for all of the SNI-97801 keys although most are not assigned to the PC keyboard due to lack of space.

Kermit 95 does support all of the 7-bit and 8-bit CH.CODE modes which are controlled by the following commands:

The CH.CODE mode determines whether the terminal communicates using International character sets such U.S. ASCII and ISO Latin 1; or whether it uses a National character set such as German. The SET TERMINAL LANGUAGE command is used to specify the default language.

The Firmware Versions numbers can be customized using the SET TERMINAL SNI-FIRWARE-VERSIONS command. The default keyboard version number is 920031 and the default terminal version number is 830851.


Automatic Actions on Switching Terminal Types

Terminal types can be switched by user command ("set terminal type"), hot key (\Ktermtype, normally assigned to Alt-t), Telnet negotiations, or (in some cases) by host escape sequence. Whenever the terminal type is set or switched:


Terminal Send Data modes

Many terminals including the Wyse and Televideo terminals support a SEND DATA feature which allows the host application to query the terminal and request that a copy of all of the data on the screen be sent to the host. This feature is very useful with applications that process a complete form of data at a time; or that allow a single terminal to be used with multiple sessions. However, this feature is also a security hole which can be exploited to steal data. Therefore, Kermit 95 disables the SEND DATA feature by default. If you need to use SEND DATA with your application, you must add a SET TERMINAL SEND-DATA ON command to your K95CUSTOM.INI file.


Click Back on your Browser's Toolbar to return.